Newborn Baby Resuscitaire Infant Radiant Warmer with Height Electric Adjusted
Fresh Carrot have 3 types:S.M.L,S from 80-150g,M from 150-200G,L 200g and up.There are 2 origin place ,one is Xiamen, Fujian province,another one is Shandong province. Character: fresh,clean,no bud,no rotten, no mouldy, no irregular shape, no presticie residue,no pest, no broken;Package:5.5kg/carton,10kg/carton, 27tons/40Rh container,we can do Fob, CNF & CIF, Payment terms must be discuss with customers, we must be make a best decision for customers.Best quality, best service.if customers no have any idea about fresh carrot,we can help our customers based on our experience.Please don't worry about your doubts about carrots and the market,We will help you earn moneyand enhance your business.We also supplied Fresh Ginger ,Air Dried Ginger , Fresh Garlic , White Garlic ,red garlic. Sweet Corn , Fresh Taro , Fresh Baby Mandarin, Fresh Red Grape, Fresh Pomelo , Fresh Ya Pear Chaotian Chili , Paprika Powder , Fresh Apple and so on.
Fresh Carrot S 80-150G,Fresh Farm Carrot,Fresh Baby Carrots,Organic Carrots Jining Fuyuan Fruits And Vegetables Co., Ltd. , http://www.fuyuanfv.com
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2Â
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2Â
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â
 Resuscitaire Neonatal  Infant Radiant Warmer With Infant Head Fixing Unit
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2Â
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2Â
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â