Jujube washing machine principle: Jujube enters the jujube washing machine sink through the conveyor belt, and is fully dispersed, tumbling, cleaning and conveying under the action of high pressure water flow and strong air bubbles. The sediment eluted from the surface of the material sinks into the bottom isolation bin, and there is no tumbling backflow to cause re-contamination. The debris and bugs floating in the water are collected through the mesh of the de-doping mechanism, and the filaments, hair, and the like are cleaned by the roller. After the washed materials are discharged, they are sprayed and washed, and sent to the next process.
How to use jujube washing machine
1, preparation before starting
1.1 Check whether the equipment has loose fasteners, whether the belt is intact or not, the net has no disconnection, residual wire, deviation, whether the water pump and the foaming machine rotate normally, whether the spray is smooth, and whether the electrical switch is normally closed. .
1.2 Fill the circulating water tank and the two bubble washers with clean water. And install the filter on the circulating water tank.
2, boot
2.1 When starting the whole processing line, first turn on the beverage pump, which is the 9th, 5th, and 4th buttons in turn. The middle pauses for a while and then turns on in turn. After all the beverage pumps are turned on normally, the bubble cleaner is turned on in turn, and the hair goes. Miscellaneous washing machine, then turn on the vibrating fabric hoist to adjust the appropriate cutting speed.
2.2 In the production, it is necessary to check in the following places: whether the vibrating fabric hoist is uniform, whether the spray pressure is insufficient, and whether the water supply is sufficient.
3. Stop before shutting down the entire production line, first stop the vibrating fabric hoist, a bubble washing machine, a hair cleaning machine, a two-bubble bubble cleaning machine, and finally close the inlet valve.
After all equipment has been shut down, first open the drain valve to drain the water from the equipment. Next, clean up the residual materials in the bubble cleaner and the hair to the residual brush. Then use a high-pressure cleaner to clean the cylinder chamber of the bubble cleaner, and the hair is removed from the cleaning machine cylinder and the filter screen of the circulating water tank. Finally turn off the power to the device and press the emergency stop button.