In the process of using the automatic labeling machine, there are always many problems encountered, and there are three most common faults. The following will be shared with you when encountering the failure of these three labeling machines. How can we solve it quickly and effectively.
1. Wrinkle treatment after labeling:
(1) The delivery rate is faster than the material running surface line rate, and the bidding rate can be adjusted.
(2) If the bidding is too early, move the measuring object to the right.
(3) The pre-out label is too long, and the pre-marking length can be adjusted.
(4) The speed of the label is not fast enough, and the speed of the label can be increased.
2, labeling machine can not paste the label processing method:
(1) The rate of bidding is too slow, and the rate of bidding can be increased.
(2) The position of the measuring electric eye is not correct, and the position of the measuring electric eye can be adjusted.
(3) The pre-out label is not long enough, and the length of the reserved label can be lengthened.
(4) The measuring object is too far away from the target end, and the measuring object can be moved to the right.
(5) The material is not detected by the measuring electric eye, and the measuring object can be adjusted.
(6) The spacing between materials is too small, and the spacing between materials can be increased.
3. The labeling machine does not process the label:
(1) The position of the measuring electric eye is not correct, and the position of the measuring electric eye can be adjusted.
(2) The measuring electric eye is faulty, and the measuring object can be replaced.
(3) The labeling head label is not enough to pull the paper, and the paper can be adjusted tightly.
(4) The color of the sticker can not be sensed by the electric eye, and the electric eye of the appropriate model can be replaced.
(5) The feeder is not opened, you can open the feeder
4, the reasons that are not sensed are usually the following points for reference:
(1) The sensitivity of the sensor switch needs to be adjusted. Solution: Need to adjust the sensitivity
(2) The sensor switch is not suitable for the object being measured. Solution: Replace the sensor switch.
(3) Causes caused by the control system, such as program control. Based on the relevant circuit. Of course, if there are other objects that can be tested, you can exclude this item.