Principle and characteristics of universal air venting hood without pipeline

background    
For many chemical laboratories, there are more or less traces of chemical leakage and poor ventilation. This directly leads to high laboratory odor and high VOC concentration, which can be equipped at indoor volatile sources. The movable universal exhaust hood will greatly improve the indoor environment, restore clean air in the laboratory, and protect the physical and mental safety of chemical laboratory workers.
image
Principle and schematic
The inside of the cabinet is equipped with a fan and a filter. The fan draws the wind at the volatilization source into the filter device of the tank through the suction hood and the pipeline, and the clean air after the filtration is directly discharged into the room.
Application range
All volatile sources with local volatility, such as chemical operation, volatilization during the working process of the instrument, soldering, etc.
Dissolution, mixing, stirring, pipetting, sampling, pH testing, Kjeldahl, HPLC, GC-MS, LC-MS...
The filter has strong adsorption capacity for organic solvents, acids, bases, perfumes, pesticides and the like.
The main parameters
1.1 Dimensions (mm): 460*460*600
1.2 Air handling capacity: 240 m3/h
1.3 Power: 30w
1.4 Current: 1.2A
1.5 Noise: ≤50dba
1.6 Voltage / Frequency: 220V/50Hz
1.7 External arm: three-armed arm - from the cover to the air inlet (the arm can be moved)
1.8 Interface inner diameter: 90mm
1.9 Operating ambient temperature: -30 ° C ~ 70 ° C
2.0 bottom roller: four total, two locking casters
structure
1.1 Metal parts: The main material is 1.2mm galvanized steel plate coated with epoxy polyester coating resistant to acid and alkali;
1.2 Filter module: polypropylene
Accessories
1.1 LED display: computerized control panel, display indoor temperature, online monitoring of air quality changes in the laboratory and display the ppm value (optional), real-time monitoring of the filter outlet chemical concentration changes and display the ppm value (optional) Highly sensitive probes for accurate measurement, showing fan speed, etc.
Alarm point setting: Users can set appropriate alarm points to improve the safety level of the laboratory.
1.2 Fan: 24 volts, American PSC imported fan, stable performance, ultra-quiet, brushless motor.
1.3 Wind chassis: galvanized steel plate, combined with the fan to ensure stable fan performance.
1.4 Interface: Anti-electromagnetic interference power cord.
Optional accessories
1.1 Filter monitoring system: It can monitor the chemical concentration change of the filter outlet in real time and display the ppm value. The alarm point can be set.
1.2 TVOC detection system: real-time online monitoring of air TVOC conditions in the laboratory and display of ppm values
1.3 Filter model: optional YJ filter, mainly for organic gases; TY filter, strong adsorption capacity for acid gases, compatible with organic gases; HEPA filter, H14, for particle filters, for particles larger than 0.3μm The filtration efficiency is 99.995%.

Antigen Extraction Tube

Antigen extraction cells refer to a class of cells that can take up, process antigens and present antigen information to T lymphocytes, also known as helper cells. In the process of thymus-dependent antigen inducing B lymphocytes to produce antibodies, not only the synergistic effect of T and B lymphocytes is required, but also the assistance of another type of cells, so this type of cells is called helper cells. It plays an important role in the body's immune recognition, immune response and immune regulation.